BODYTONE_17

Spectrum Bodytone 8-Channel (16 Pads) EMS Machine User Manual

Model: BODYTONE_17

1. Introduction to Neuromuscular Stimulation

The Spectrum Bodytone 8-Channel (16 Pads) EMS Machine utilizes neuromuscular stimulation (NMS) technology. This process involves using low-frequency electrical currents to induce muscle contractions. These electrical impulses mimic the natural signals sent by the brain to initiate muscle movement.

Electrical impulses are delivered to individual muscles or muscle groups via lead wires and electrodes (pads). This creates a rhythmic contraction and relaxation cycle in the muscle, which can assist in relieving muscle spasms, re-educating muscles, improving range of motion, and restoring motor control. It also helps prevent or reduce muscle atrophy from disuse and enhances local blood circulation. The treatment is generally safe and, after an initial tingling sensation, can be a relaxing experience.

Spectrum Bodytone EMS Machine with control panel and text describing benefits and features

Image: The Spectrum Bodytone EMS Machine, showcasing its design and highlighting key features and benefits.

2. Lietošanas priekšrocības

Regular and proper use of the Spectrum Bodytone EMS Machine can provide several benefits:

  • Figure Toning: Assists in toning muscles for improved body contour.
  • Body Firming: Contributes to overall body firming.
  • Post-Natal Improvement: Can aid in muscle recovery and strengthening after childbirth.
  • Fat Breakdown: Enhances local breakdown of fat deposits.
  • Muscle Uplift: Helps to uplift sagging areas such as the abdomen, buttocks, and thighs.

3. Galvenās iezīmes

The Spectrum Bodytone EMS Machine is designed with user convenience and effectiveness in mind:

  • 8 Channels, 16 Pads Output: Allows for comprehensive treatment of multiple muscle groups simultaneously.
  • Digital Treatment Timer: Provides precise control over session duration.
  • Trīs darbības režīmi: Includes modes for inch loss, fat loss, and toning/firming, catering to different user needs.
  • Independent Power Controls: Each channel features independent power adjustment for customized intensity.
  • Vienkārša darbība: User-friendly interface for straightforward use.

4. Iestatīšanas instrukcijas

  1. Izpakojiet ierīci: Carefully remove the EMS machine and all accessories from its packaging.
  2. Pievienojiet strāvu: Plug the power adapter into the machine's power input, then connect it to a suitable electrical outlet. Ensure the power switch on the device is in the 'OFF' position before connecting.
  3. Pievienojiet vadus: Connect the lead wires to the designated output channels on the front panel of the machine. Each channel typically supports two pads.
  4. Prepare Electrodes (Pads): Ensure the electrode pads are clean and have sufficient conductive gel or are self-adhesive. If using conductive gel, apply a thin, even layer to the entire surface of the pad.
  5. Attach Pads to Lead Wires: Securely attach the electrode pads to the ends of the lead wires.
  6. Placement of Pads: Refer to the 'Pad Placement Guidelines' section for proper placement on the body. Ensure pads are placed on clean, dry skin.

5. Lietošanas instrukcijas

  1. Ieslēgšana: Turn the main power switch to the 'ON' position. The digital display should illuminate.
  2. Iestatiet ārstēšanas laiku: Use the digital treatment timer controls to set your desired session duration. Consult a professional or start with shorter durations (e.g., 15-20 minutes).
  3. Izvēlieties režīmu: Choose one of the three available modes (inch loss, fat loss, or toning/firming) according to your treatment goal.
  4. Pielāgojiet intensitāti: Slowly turn the independent power control knobs for each channel to gradually increase the intensity. Start with the lowest setting and increase until you feel a comfortable, yet noticeable, muscle contraction. Avoid setting the intensity too high, which can cause discomfort.
  5. Monitor Sensation: Throughout the session, ensure the sensation remains comfortable. If any discomfort occurs, reduce the intensity or stop the session.
  6. Beigu sesija: Once the timer completes, the machine will automatically turn off, or you can manually turn off the power switch.
  7. Remove Pads: Gently remove the electrode pads from your skin. Disconnect them from the lead wires.

6. Pad Placement Guidelines

Proper placement of electrode pads is crucial for effective and safe muscle stimulation. A pair of pads from the same channel should be placed at the origin and insertion points of the target muscles. Pads must be of proper size and conductivity, as suggested by the manufacturer. Always use a water-based, salt-free gel for proper conduction if your pads require it.

Diagram showing electrode pad placement on the anterior and posterior human body for electronic muscle stimulators

Image: Detailed diagram illustrating recommended electrode pad placement on various muscle groups of the human body (front and back views) for optimal stimulation.

Person with electrode pads placed on the thigh and abdominal area

Attēls: Piemample of electrode pad placement on a person's leg and lower abdomen.

Person with electrode pads placed on the lower back and gluteal area

Attēls: Piemample of electrode pad placement on a person's lower back and gluteal region.

7. Electrical Frequencies for Health & Beauty

The Bodyliner, a type of electronic muscle stimulator, is designed for professional use in clinics, gyms, and hospitals to provide relaxing and pleasant treatments for body shaping. It offers an effortless and time-saving method to exercise muscles through what is often referred to as "passive exercise."

When applied correctly and confidently, electrical therapy can produce effects that are not achievable through manual methods or cosmetics. It also reinforces and accelerates the results of a clinical program.

The primary purpose of using electrical current is to stimulate or enhance natural bodily processes. As the body possesses its own natural electrical energy, specific electrical frequencies can be effectively used to encourage the body to function at its full capacity, regain vitality, and improve strength. Small electrical currents generated by individual cells naturally support the body's processes. This activity can be further enhanced by carefully selecting and utilizing Spectrum's electrical therapy equipment to restore proper body function.

Text describing electrical frequencies for health and beauty, and the benefits of electrical therapy

Image: Informational text detailing the principles and benefits of electrical frequencies in health and beauty applications.

8. Contraindications of Electrical Therapy

Electrical currents should only be used in beauty therapy when the client is healthy. In cases of poor or erratic health, or even a suspicion of illness, treatment should not be carried out.

Contraindications, which prevent electrical therapy, include:

  • All existing and suspected diseases.
  • Cases of inflammation or fever.
  • History of thrombosis, especially using caution in areas where thrombosis has occurred.
  • All forms of tuberculosis, tumors, etc.
  • Any metal inserts, cardiac pacemakers, hip replacement, joints, plates in bones.
  • All areas with various veins protruding on the surface of the skin.
  • Areas of circulatory disorders, edema (swelling, fluid retention), varicose veins, ulcers, etc.
  • Pregnancy – No treatment in the abdominal and lower back areas, especially during the first three months. Special care is required.
  • Preferably no treatments on any areas during menstruation.
  • Regions with a reduced sense of feeling (hypoesthesia), due to the difficulty of assessing reaction.
  • History of nervous illness, mental breakdown, or acute depression.

9. Piesardzības pasākumi un brīdinājumi

  • Electrode must not be placed in such a position as to pass current into the carotid gland area.
  • Must not be used with a demand-type cardiac pacemaker.
  • Electrodes must not be placed to pass current cerebrally through the head.
  • Jāievēro piesardzība pacientiem ar aizdomām vai diagnosticētu epilepsiju.
  • Caution should be used when there is a tendency for hemorrhage following acute trauma or fracture.
  • Caution should be used following recent surgical procedures, when muscle contraction may disrupt the healing process.
  • Skin irritation may occur at the site of electrode placement following long-term application or inadequate jelly/water applied on electrodes before placing them for treatment.
  • Possible allergic reactions due to electrodes may occur.
  • Keep unit out of children's reach.
  • Tikai ārējai lietošanai.
Text detailing contraindications and precautions for electrical therapy

Image: Informational text outlining contraindications and important precautions to observe when using electrical therapy devices.

10. Apkope

  1. Iekārtas tīrīšana: Noslaukiet galveno ierīci ar mīkstu, damp drānu. Nelietojiet abrazīvus tīrīšanas līdzekļus un neiegremdējiet ierīci ūdenī.
  2. Tīrīšanas spilventiņi: If your pads are reusable and require cleaning, follow the manufacturer's instructions for cleaning and storage. Replace pads when they lose their adhesiveness or conductivity.
  3. Uzglabāšana: Store the device and accessories in a cool, dry place, away from direct sunlight and extreme temperatures. Keep out of reach of children.
  4. Kabeļa kopšana: Inspect lead wires regularly for any signs of damage. Do not bend or twist cables excessively.

11. Traucējummeklēšana

  • Nav jaudas: Ensure the power adapter is securely plugged into both the unit and the electrical outlet. Check if the power switch is in the 'ON' position.
  • Nav sajūtu/vāja sajūta:
    • Verify that the electrode pads are firmly attached to the skin and are properly conductive (apply more gel if needed).
    • Check that lead wires are securely connected to both the unit and the pads.
    • Gradually increase the intensity knob for the specific channel.
    • Ensure pads are not expired or worn out; replace if necessary.
  • Discomfort/Pain: Immediately reduce the intensity. Re-evaluate pad placement to ensure they are not over bony areas or sensitive skin. If discomfort persists, discontinue use and consult a healthcare professional.
  • Ādas kairinājums: Ensure skin is clean and dry before application. Use hypoallergenic pads if sensitive. Discontinue use if irritation persists.

12. Specifikācijas

FunkcijaDetaļas
RažotājsVispārējs
Modeļa numursBODYTONE_17
Kanāli8
Pads Output16
Ārstēšanas taimerisDigitālais
Darbības režīmiInch Loss, Fat Loss, Toning/Firming
Independent ControlsYes, for each channel
Preces svars111 kg
Iepakojuma izmēri111 x 111 x 111 cm
Datums pirmais pieejams4. gada 2022. septembris

13. Garantija un atbalsts

Specific warranty information for the Spectrum Bodytone 8-Channel (16 Pads) EMS Machine is not provided in the available product details. Please refer to the product packaging or contact the retailer/manufacturer directly for warranty terms and conditions.

For technical support or inquiries regarding the operation and maintenance of your device, please contact the manufacturer, Generic, or your point of purchase.

Documents - BODYTONE_17 – BODYTONE_17

nav atbilstošu dokumentu