1. Ievads
This manual provides essential instructions for the safe and efficient operation, setup, and maintenance of your VEVOR VP125 Vacuum Chamber Kit. This kit is designed for degasification and de-bubbling applications, particularly for materials like resin, silicone, and epoxy. Please read this manual thoroughly before initial use and retain it for future reference.

This image displays the complete VEVOR vacuum pump and chamber kit, highlighting its key performance metrics: a 3.5 m³/min flow rate, a single-stage pump design, and an impressive 5 Pa ultimate vacuum for efficient degasification.
2. Drošības instrukcijas
Adhere to all safety precautions to prevent injury or damage to the equipment.
- Always operate the vacuum pump in a well-ventilated area.
- Pirms sūkņa iedarbināšanas pārliecinieties, vai visi savienojumi ir droši un bez noplūdēm.
- Do not operate the pump without sufficient vacuum pump oil. Check oil levels regularly.
- Avoid direct contact with the vacuum pump during operation, as it may become hot.
- Wear appropriate personal protective equipment (PPE), such as safety glasses, when handling chemicals or operating the vacuum system.
- Keep the equipment away from flammable materials and sources of ignition.
- Pirms jebkādas apkopes vai tīrīšanas atvienojiet strāvas padevi.
- Do not use the vacuum chamber for storing or processing hazardous or corrosive materials unless specifically designed for such use.
3. Iepakojuma saturs
Izpakojot iepakojumu, pārliecinieties, vai visas sastāvdaļas ir savās vietās un nav bojātas.
- 1 x Single-Stage Vacuum Pump (3.5 CFM)
- 1 x Vacuum Chamber (1.5 Gallons / 5.67 Liters, Stainless Steel)
- 1 x Acrylic Vacuum Chamber Lid
- 1 x Set of Vacuum Gauges and Valve Assembly
- 1 x Vacuum Hose (approximately 1.5 meters / 4.92 ft)
- 1 x Silikona spilventiņš
- 1 x Bottle of Vacuum Pump Oil (approx. 330 ml)
- 1 x Toolbox (with wrench and intake filter)

A clear layout of all items supplied with the VEVOR vacuum chamber kit, ensuring users can verify package contents upon receipt. This includes the vacuum pump, 1.5-gallon chamber, pressure gauge assembly, vacuum hose, vacuum pump oil, a wrench, and a screwdriver.
4. Iestatīšana
Follow these steps to assemble your vacuum chamber kit:
- Prepare the Vacuum Pump: Ensure the vacuum pump is placed on a stable, level surface. Check the oil level in the pump's sight glass. If low, add the provided vacuum pump oil until it reaches the 'MAX' mark.
- Connect the Gauge Assembly: Attach the vacuum gauge and valve assembly to the vacuum chamber lid. Ensure all threaded connections are tightened securely to prevent leaks.
- Attach the Vacuum Hose: Connect one end of the vacuum hose to the valve assembly on the chamber lid and the other end to the intake port of the vacuum pump. Ensure connections are tight.
- Place Silicone Pad: Position the silicone pad inside the vacuum chamber. This helps protect the chamber bottom and provides a stable surface for items being degassed.
- Novietojiet vāku: Place the acrylic lid onto the vacuum chamber. Ensure it is centered and creates an even seal with the chamber's rim. The lid's weight and the vacuum itself will help create a tight seal.

Detalizēts view of the vacuum chamber's lid, emphasizing its leak-proof design. It features a securely sealed threaded connection for the gauge and an airtight cover, crucial for maintaining high vacuum pressure during operation.

A detailed diagram identifying the robust components of the VEVOR kit. For the pump: T-shaped heat sink, die-cast aluminum housing, oil sight glass, and exhaust filter. For the chamber: silicone oil vacuum gauge, silencer, transparent acrylic cover, and 1.50m vacuum hose.
5. Lietošanas instrukcijas
This section outlines the procedure for degasifying materials using your VEVOR vacuum chamber kit.
- Materiāla sagatavošana: Place the material to be degassed (e.g., resin, silicone) into a suitable container that fits inside the vacuum chamber. Ensure the container is not filled to the brim, as materials may expand under vacuum.
- Load Chamber: Carefully place the container with the material onto the silicone pad inside the vacuum chamber.
- Seal Chamber: Place the acrylic lid firmly onto the chamber, ensuring a good seal.
- Start Vacuum Pump: Close the valve on the gauge assembly. Plug in the vacuum pump and turn it on.
- Open Valve: Slowly open the valve on the gauge assembly to begin drawing a vacuum in the chamber. Observe the vacuum gauge for pressure reduction.
- Monitor Degassing: As the vacuum is drawn, air bubbles will rise and escape from your material. Monitor this process through the transparent lid. Materials may expand significantly before settling. Do not allow material to overflow.
- Maintain Vacuum: Once the desired vacuum level is reached (e.g., 5 Pa), close the valve on the gauge assembly and turn off the vacuum pump. The chamber should hold the vacuum.
- Atbrīvošanas vakuums: After the degasification process is complete (typically when bubbling stops), slowly open the air release valve on the gauge assembly to equalize the pressure inside the chamber. Do not open too quickly, as this can disturb the material.
- Remove Material: Once the pressure is equalized, remove the lid and retrieve your degassed material.

This graphic illustrates the internal structure of the vacuum pump's 4-pole pure copper motor, highlighting its design for stable performance, high efficiency, quick heat dissipation, extended durability, and reduced operational noise.

The vacuum chamber is shown in various applications, illustrating its versatility for degasifying resin, silicone, and plaster. The image also indicates the chamber's 5.7-liter capacity.
6. Apkope
Regular maintenance ensures the longevity and optimal performance of your vacuum kit.
- Vacuum Pump Oil Change: Change the vacuum pump oil regularly, especially after prolonged use or if the oil appears cloudy or discolored. Refer to the pump's specific instructions for oil change procedures.
- Clean Chamber: After each use, clean the inside of the vacuum chamber and the acrylic lid with a soft cloth and a mild, non-abrasive cleaner. Ensure no residue remains that could affect future seals.
- Pārbaudiet blīves: Periodically inspect the rubber gasket on the vacuum chamber lid for cracks, tears, or deformation. Replace if necessary to maintain an airtight seal.
- Check Hose: Examine the vacuum hose for any kinks, cracks, or damage. A damaged hose can lead to vacuum leaks.
- Uzglabājiet pareizi: When not in use, store the vacuum kit in a clean, dry environment, protected from dust and extreme temperatures.
7. Traucējummeklēšana
Biežāk sastopamās problēmas un to risinājumus skatiet šajā sadaļā.
| Problēma | Iespējamais cēlonis | Risinājums |
|---|---|---|
| Pump runs but no vacuum is achieved. | Loose connections, damaged hose, lid not sealed, low oil. | Check all hose connections and valve positions. Ensure the lid is properly seated. Inspect the hose for damage. Check and refill pump oil. |
| Vacuum level drops quickly after pump is turned off. | Leak in the system (chamber, lid, hose, or connections). | Inspect the chamber gasket, lid, hose, and all fittings for leaks. Tighten connections. Replace damaged components. |
| Pump is excessively noisy or vibrates. | Low oil level, contaminated oil, pump malfunction. | Check oil level and add/change oil if necessary. If problem persists, contact support. |
| Material overflows in chamber. | Container too full, material expands too rapidly. | Use a larger container or fill less. Slowly open the vacuum valve to control pressure drop. |
8. Specifikācijas
Key technical specifications for the VEVOR VP125 Vacuum Chamber Kit.
- Modeļa numurs: VP125
- Free Air Displacement: 3.5 CFM (99 l/min)
- Galīgais vakuums: 5 Pa
- Vacuum Chamber Capacity: 1.5 litri (5.67 litri)
- Sūkņa eļļas jauda: 0.27 qt. / 260 ml
- Ieplūdes stiprinājums: 1/4" SAE
- Neto svars: 8.5 kg (18.73 mārciņas)
- Sūkņa izmēri (G x P x A): 275 x 120 x 225 mm (10.83 x 4.72 x 8.86 collas)
- Chamber Dimensions (Diameter x Height): 225 x 150 mm (8.86 x 5.91 collas)
- Materiāls: Stainless Steel (Chamber), Aluminum (Pump Housing), Acrylic (Lid)

This image provides precise measurements for both the VP125 vacuum pump and the 1.5-gallon vacuum chamber, including overall dimensions and key performance specifications like free air displacement and ultimate vacuum.
9. Garantija un atbalsts
VEVOR produkti ir izstrādāti izturībai un veiktspējai. Lai saņemtu informāciju par garantiju vai tehnisko atbalstu, lūdzu, skatiet produktam pievienoto garantijas karti vai apmeklējiet oficiālo VEVOR vietni. website. Please have your model number (VP125) and purchase date available when contacting support.