1. Drošības informācija
BRĪDINĀJUMS: Nepareiza uzstādīšana, regulēšana, pārveidošana, apkope vai apkope var izraisīt īpašuma bojājumus, ievainojumus vai nāvi. Pirms šī aprīkojuma uzstādīšanas vai apkopes rūpīgi izlasiet šīs instrukcijas.
- Always disconnect electrical power to the furnace before installing or servicing the ignition module.
- Uzstādīšana un apkope jāveic kvalificētam uzstādītājam, servisa aģentūrai vai gāzes piegādātājam.
- Pārliecinieties, vai visi elektroinstalācijas savienojumi atbilst vietējiem un valsts elektrības noteikumiem.
- Neapiet nekādas drošības ierīces.
- Uzstādīšanas un apkopes laikā valkājiet atbilstošus individuālos aizsardzības līdzekļus (IAL).
2. Produkts beidziesview
The Generic Carrier HVAC 1007-100 2310 Ignition Module is a critical component designed to control the ignition sequence and monitor the flame in compatible Carrier furnace systems. This module operates at 24 Volts, 60HZ, ensuring reliable and safe operation of your heating system.
It is engineered to fit various Carrier HVAC models, including 58GS 150 160LA, 58DR 075 141AB, and 58GS 125 160GB, providing a direct replacement for the original part.

2.1. attēls. Priekšpuse view of the 1007-100 2310 Ignition Module, showing its general appearance and housing.
3. Instalācijas rokasgrāmata
This section provides general instructions for replacing an existing ignition module. Always refer to your specific furnace model's service manual for detailed wiring diagrams and procedures.
3.1 Pirmsinstalēšanas soļi
- Atvienot barošanu: Turn off the electrical power to the furnace at the main service panel. Verify power is off using a voltage metrs.
- Access Module: Locate the existing ignition module within the furnace control compartment.
- Dokumentu elektroinstalācija: Before disconnecting any wires, take clear photos or draw a diagram of all wire connections to the old module. Note the color and terminal location of each wire.
3.2 Moduļa nomaiņa
- Noņemt veco moduli: Carefully disconnect all wires from the old ignition module. Unmount the old module from its position.
- Mount New Module: Position the new 1007-100 2310 Ignition Module in the same location as the old one. Secure it using the appropriate screws or mounting hardware.
- Pievienojiet vadu: Refer to your documented wiring diagram and connect each wire to the corresponding terminal on the new module. Ensure all connections are secure and tight.

3.1. attēls. Aizmugure view of the ignition module, highlighting the various wiring connectors for installation.

3.2. attēls: sāni view of the ignition module, showing the mounting tabs for secure installation within the furnace.
3.3. Pārbaudes pēc uzstādīšanas
- Pārbaudiet savienojumus: Double-check all wire connections for correctness and security.
- Atjaunot jaudu: Ieslēdziet krāsni elektrisko strāvu.
- Pārbaudes darbība: Initiate a call for heat from the thermostat and observe the furnace's ignition sequence. Ensure the burner ignites smoothly and operates correctly.
- Pārbaudiet, vai nav noplūdes: Ja gāzes vadi ir bojāti, pārbaudiet, vai nav gāzes noplūdes, izmantojot ziepju šķīdumu.
4. Darbība
The 1007-100 2310 Ignition Module manages the furnace's ignition process. When a call for heat is received from the thermostat, the module initiates a sequence:
- It activates the draft inducer motor to clear the combustion chamber.
- It then energizes the igniter (either hot surface igniter or spark igniter) to create a flame source.
- Simultaneously, it opens the gas valve to allow gas flow to the burners.
- Once ignition occurs, the module uses a flame sensor to confirm the presence of a flame.
- If a flame is detected, the module continues to monitor it throughout the heating cycle. If no flame is detected within a specified time, the module will attempt re-ignition or enter a lockout state for safety.
5. Apkope
The ignition module itself requires minimal maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and proper function.
- Ikgadējā krāsns pārbaude: Have a qualified HVAC technician inspect your furnace annually. They will check all components, including the ignition system, for wear or malfunction.
- Turiet teritoriju brīvu: Ensure the area around the furnace is free from dust, debris, and flammable materials.
- Pārbaudiet vadu: During annual inspections, ensure all wiring connections to the module are secure and free from corrosion or damage.
6. Traucējummeklēšana
If your furnace is experiencing issues related to ignition, consider the following troubleshooting steps. Always ensure power is disconnected before inspecting internal components.
| Simptoms | Iespējamais cēlonis | Darbība |
|---|---|---|
| No ignition, no spark/glow | No power to module, faulty igniter, faulty module, wiring issue | Check power supply. Inspect igniter for damage. Verify wiring connections. Test module for proper voltage (professional recommended). |
| Igniter glows/sparks, but no flame | No gas supply, faulty gas valve, clogged burner, faulty module | Check gas supply to furnace. Inspect gas valve operation. Clean burners. |
| Burner ignites, then immediately shuts off | Dirty or faulty flame sensor, poor ground connection, faulty module | Clean flame sensor rod. Check furnace grounding. |
| Intermitējoša aizdegšanās | Loose wiring, weak igniter, draft issues, faulty module | Inspect all wiring. Check igniter resistance. Ensure proper furnace venting. |
If troubleshooting steps do not resolve the issue, it is recommended to contact a qualified HVAC technician for diagnosis and repair.
7. Specifikācijas
- Modeļa numurs: 1007-100 2310
- Voltage: 24 volts
- Biežums: 60 HZ
- Produkta izmēri: Aptuveni 7.5 x 4.1 x 2.4 collas
- Ražotājs: Vispārējs
- Saderība: Fits Carrier HVAC 58GS 150 160LA, 58DR 075 141AB, 58GS 125 160GB, and similar models.
8. Garantija un atbalsts
This product is covered by the manufacturer's standard warranty. Please refer to the packaging or contact the retailer for specific warranty terms and conditions. For technical support or assistance, please contact the vendor or a qualified HVAC professional.