PILZ 750103

Pilz PNOZ s3 Safety Relay Instruction Manual

Model: 750103 | Brand: PILZ

1. Ievads

The Pilz PNOZ s3 is a compact safety relay designed for monitoring safety functions in industrial applications. It is specifically engineered to monitor E-STOP pushbuttons, safety gates, and light grids, ensuring the safe operation of machinery by reliably detecting and reacting to hazardous conditions. This manual provides essential information for the proper installation, operation, and maintenance of the PNOZ s3 safety relay.

2. Drošības informācija

Svarīgi: Read and understand all safety instructions before installing, operating, or performing maintenance on the PNOZ s3 safety relay. Failure to comply with these instructions may result in serious injury or death, and/or damage to the equipment.

3. Produkts beidziesview

The Pilz PNOZ s3 safety relay features a compact design with clearly labeled terminals and status indicators on the front panel. It is designed for plug-in mounting, allowing for easy installation and replacement.

Pilz PNOZ s3 Safety Relay front view with terminals and indicators

1. attēls. Priekšpuse view of the Pilz PNOZ s3 Safety Relay, showing input/output terminals and status indicators.

3.1. Termināļi

The relay is equipped with screw terminals for secure electrical connections. Key terminals include:

3.2. Rādītāji

The front panel includes LED indicators to provide status information:

4. Iestatīšana un instalēšana

4.1. Montāža

The PNOZ s3 is designed for plug-in mounting onto a compatible base or DIN rail adapter. Ensure the mounting location is free from excessive vibration, moisture, and extreme temperatures. Allow adequate space for ventilation and wiring.

4.2. Elektroinstalācija

All wiring must be performed according to the provided wiring diagrams from PILZ and relevant electrical standards. Use appropriate wire gauges and ensure all connections are secure to prevent loose contacts.

5. Lietošanas instrukcijas

Once properly installed and wired, the PNOZ s3 safety relay operates by monitoring the status of its input circuits. When all safety inputs are closed (e.g., E-STOP released, safety gate closed), and after a successful reset, the safety outputs will close, allowing the machine to operate. If any safety input opens, the outputs will immediately open, bringing the machine to a safe state.

5.1. Sākotnējā ieslēgšana un atiestatīšana

5.2. Normāla darbība

During normal operation, the 'Power', 'In1', 'In2', and 'Out' LEDs should be illuminated, indicating that the safety circuit is closed and the machine is enabled. If a safety function is activated (e.g., E-STOP pressed, safety gate opened), the corresponding input LED(s) will change state, and the 'Out' LED will turn off as the safety outputs open.

6. Apkope

The Pilz PNOZ s3 safety relay is designed for minimal maintenance. Regular inspections are recommended to ensure continued safe operation.

7. Traucējummeklēšana

This section provides guidance for common issues encountered with the PNOZ s3 safety relay.

SimptomsIespējamais cēlonisRisinājums
Fault indicator (LED) is on.Internal fault, wiring error, or short circuit in the safety circuit.Check wiring for shorts or open circuits. Verify power supply. If fault persists, contact PILZ support.
No power LED illumination.Nav barošanas avota, nepareizs skaļumstage, or faulty wiring to A1/A2.Verify 24VDC power supply. Check connections to A1 and A2.
Outputs not activating (Out LED off).Safety inputs not closed, reset not performed, or internal fault.Ensure all safety inputs are in their safe state. Perform a manual reset if required. Check input LEDs.
Inputs (In1, In2) LEDs not illuminating correctly.Faulty safety device, wiring issue to input terminals, or incorrect input configuration.Check the connected safety devices (E-STOP, safety gate). Verify wiring to S11, S12, S21, S22, S34.

8. Specifikācijas

Key technical specifications for the Pilz PNOZ s3 safety relay (Model: 750103):

9. Garantija un atbalsts

For detailed warranty information, please refer to the official PILZ warranty policy available on their website or contact your authorized PILZ distributor. In case of technical issues or questions not covered in this manual, please contact PILZ technical support for assistance. Ensure you have the model number (750103) and serial number of your device ready when contacting support.

PILZ Official Webvietne: www.pilz.com