1. Ievads
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of the Danfoss 077B6827 Temperature Control. This digital, wired temperature controller is designed for precise temperature regulation in various applications. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Drošības informācija
- Elektrības apdraudējums: Installation and servicing must be performed by qualified personnel only. Disconnect all power to the unit before performing any work.
- Pareiza lietošana: Use this device only for its intended purpose as a temperature control. Any other use may result in damage or injury.
- Vides apstākļi: Ensure the operating environment is within the specified temperature and humidity ranges to prevent malfunction.
- Komponentu integritāte: Do not operate the device if any components appear damaged.
3. Produkts beidziesview
The Danfoss 077B6827 is a robust temperature control unit featuring a rotary knob for manual adjustments and digital connectivity for advanced control. It includes a main control module and a capillary tube sensor for accurate temperature measurement.

- Vadības bloks: The main body housing the electrical components and the rotary control knob.
- Rotācijas poga: Used for setting the desired temperature or operational mode.
- Capillary Tube Sensor: A thin metallic tube containing a temperature-sensitive fluid, used to detect ambient or process temperature.
- Elektroinstalācijas spailes: Located on the control unit for electrical connections.
4. Iestatīšana un instalēšana
Uzstādīšana jāveic kvalificētam tehniķim.
- Strāvas atslēgšana: Ensure the main power supply to the equipment where the control will be installed is completely disconnected.
- Montāža: Mount the control unit in a suitable location, typically a wall mount, ensuring it is secure and accessible for adjustments. Refer to the included mounting hardware and instructions.
- Elektroinstalācija: Connect the control unit to the electrical system using the provided wiring harness. Follow the wiring diagram specific to your application. This is a wired connectivity device.
- Sensora izvietojums: Position the capillary tube sensor in the area where temperature is to be measured. Ensure the sensor is not kinked or damaged and is free from external heat sources or drafts that could affect accuracy.
- Akumulatora uzstādīšana: As this unit is battery-powered, install the required batteries according to the polarity markings.
- Strāvas pieslēgums: Once all connections are secure and verified, restore power to the system.
5. Lietošanas instrukcijas
The Danfoss 077B6827 offers both manual and digital control options.
- Manual Temperature Setting: Use the rotary knob on the front of the unit to select the desired temperature or operational setting. The knob typically features numerical indicators (e.g., 0-8) corresponding to different temperature ranges or control levels.
- Digitālais displejs: The unit features a digital display for clear indication of current settings or measured temperature.
- Lietotņu vadība: For advanced control and monitoring, the device supports app control. Refer to the specific Danfoss app documentation for pairing and usage instructions.
- BACnet MS/TP Connectivity: This controller can be integrated into Building Management Systems (BMS) via BACnet MS/TP protocol for centralized control and data exchange. Consult your BMS administrator for integration details.
6. Apkope
- Tīrīšana: Periodically clean the exterior of the control unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the unit.
- Akumulatora nomaiņa: When the battery indicator signals low power, replace the batteries promptly to ensure continuous operation. Refer to the battery compartment for correct battery type and polarity.
- Sensora pārbaude: Regularly inspect the capillary tube sensor for any signs of damage, kinks, or corrosion. Ensure it remains securely positioned.
- Profesionāla pārbaude: It is recommended to have the system professionally checked annually to ensure optimal performance and calibration.
7. Traucējummeklēšana
If you encounter issues, perform the following basic checks before contacting support.
- Nav strāvas/ierīce nereaģē:
- Check if the main power supply to the system is active.
- Verify that the batteries are correctly installed and not depleted. Replace if necessary.
- Pārbaudiet visus vadu savienojumus, vai tie nav vaļīgi vai bojāti.
- Nepareizi temperatūras rādījumi:
- Ensure the capillary tube sensor is correctly positioned and not obstructed.
- Check for any physical damage to the sensor tube.
- Verify that the sensor is not exposed to unintended heat sources or drafts.
- Control Not Adjusting Temperature:
- Confirm the rotary knob is set to the desired position.
- If using app control, ensure the app is connected and sending commands correctly.
- Check for any error messages on the digital display or within the app.
If problems persist after performing these checks, contact Danfoss technical support.
8. Specifikācijas
| Funkcija | Detaļas |
|---|---|
| Zīmols | Danfoss |
| Modeļa numurs | 077B6827 (Item model number: 46-1387) |
| Kontrollera tips | Rotary Knob / Push Button |
| Krāsa | Melns |
| Īpaši lietojumi | Temperatūras kontrole |
| Temperatūras kontroles veids | Digitālais |
| Savienojamības tehnoloģija | Vadu |
| Iekļautie komponenti | 1 x Thermostat, 1 x Wiring Harness |
| Barošanas avots | Darbojas ar baterijām |
| Preces svars | 6.7 unces |
| Displeja veids | Digitālais |
| Kontroles metode | Lietotne, grozāmā poga |
| Savienojamības protokols | BACnet MS/TP |
| Montāžas veids | Sienas stiprinājums |
| Fona apgaismojums | Nē |
| UPC | 254613875887 |
9. Garantija un atbalsts
For information regarding product warranty, technical support, or service, please refer to the official Danfoss website or contact your local Danfoss distributor. You can also visit the Danfoss veikals vietnē Amazon lai iegūtu papildu informāciju par produktu.