Apera Instruments AI1107

Apera Instruments 3M KCL Storage Soaking Solution

Modelis: AI1107

Brand: Apera Instruments

Produkts beidziesview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

Galvenās funkcijas ietver:

Uzstādīšana un sagatavošana

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

Attēls: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

Lietošanas instrukcijas

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. Noņemiet elektroda aizsargvāciņu.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Rūpīgi notīriet elektrodu.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

Problēmu novēršana

This section addresses common issues related to electrode performance and how the storage solution can help.

ProblēmaIespējamais cēlonisRisinājums
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

Specifikācijas

AtribūtsDetaļas
Produkta nosaukums3M KCL Storage Soaking Solution
Modeļa numursAI1107
ZīmolsApera instrumenti
Vienuma apjoms8 šķidruma unces (aptuveni 236 ml)
KCL Concentration3M (3 mol/L)
Vienuma formaŠķidrums
Informācija par iepakojumuPudele
Produkta izmēri6.3 x 1.97 x 2.36 collas
Preces svars9 unces
Izcelsmes valstsASV

Garantijas informācija

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webvietnē vai sazinieties tieši ar viņu klientu atbalsta dienestu.

Atbalsts un sazināšanās

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webvietne:

www.aperainst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

Saistītie dokumenti — AI1107

Iepriekšview Apera SX811-SS pārnēsājamais pH mērītājs pārtikas testēšanai: lietošanas instrukcija un specifikācijas
Visaptveroša lietošanas instrukcija un tehniskās specifikācijas Apera SX811-SS pārnēsājamajam pH metram, kas paredzēts precīzai pārtikas testēšanai. Uzziniet par funkcijām, kalibrēšanu, iestatīšanu, USB saziņu un problēmu novēršanu.
Iepriekšview ORP60-Z Smart ORP/Redox Tester User Manual
User manual for the Apera Instruments ORP60-Z Smart ORP/Redox Tester, covering features, installation, operation, calibration, maintenance, technical specifications, and warranty. Includes detailed instructions and troubleshooting.
Iepriekšview PH60Z-HT viedā pH mērītāja lietotāja rokasgrāmata — Apera Instruments
Apera Instruments PH60Z-HT viedā pH mērītāja lietotāja rokasgrāmata, kurā detalizēti aprakstītas tā funkcijas, darbība, kalibrēšana, apkope un problēmu novēršana, lietojot augstas temperatūras un kodīgos šķīdumus.
Iepriekšview PH60Z-PW Smart pH-Meter Bedienungsanleitung für reines Wasser
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Smart pH-Meter. Erfahren Sie mehr über Kalibrierung, Messung, Wartung und technische Daten für präzise pH-Messungen in reinem Wasser.
Iepriekšview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
Iepriekšview Apera Instruments SX731 portatīvā pH/vadītspējas/ORP mērītāja lietotāja rokasgrāmata
Apera Instruments SX731 portatīvā pH/vadītspējas/ORP mērītāja lietotāja rokasgrāmata, kurā aprakstītas tā funkcijas, tehniskās specifikācijas, darbība, kalibrēšana, apkope un garantija.