1. Ievads
This manual provides essential information for the installation, operation, maintenance, and troubleshooting of the Juniper Networks EX4200-24P 24-Port Power over Ethernet (PoE) Ethernet Switch. The EX4200-24P is designed to provide high-performance, reliable network connectivity for enterprise and data center environments, offering 24 Gigabit Ethernet ports with PoE+ capabilities and Layer 3 features.
2. Drošības informācija
Lai novērstu traumas un aprīkojuma bojājumus, ievērojiet šādus drošības pasākumus:
- Nodrošiniet pareizu ierīces zemējumu.
- Nelietojiet slēdzi mitrā vai pārmērīgi mitrā vidē.
- Pirms jebkādu apkopes vai uzstādīšanas procedūru veikšanas atvienojiet strāvas padevi.
- Izmantojiet tikai apstiprinātus strāvas vadus un piederumus.
- Ensure adequate ventilation around the switch to prevent overheating.
3. Iepakojuma saturs
Pārbaudiet, vai jūsu iepakojumā ir šādas preces:
- Juniper Networks EX4200-24P Ethernet Switch
- Strāvas vads
- Rack-mount Kit (brackets, screws)
- Konsoles kabelis (RJ-45 līdz DB-9)
- Dokumentācija (īsās lietošanas pamācība, drošības informācija)
Note: Contents may vary based on the specific renewed product offering.
4. Fiziskais pārsvarsview
4.1 Priekšējais panelis

Figure 4.1: Front Panel of EX4200-24P Switch. This image displays the front of the Juniper Networks EX4200-24P switch, featuring 24 RJ-45 Gigabit Ethernet ports, each with LED indicators, and four SFP+ uplink ports on the right side, along with a small LCD display and control buttons.
The front panel of the EX4200-24P switch includes:
- 24 x 10/100/1000BASE-T Ethernet Ports: RJ-45 connectors for network devices. Each port supports Power over Ethernet Plus (PoE+).
- Portu statusa gaismas diodes: Indicators for link status, activity, and PoE status for each port.
- Uplink Module Slot: Typically houses 4x SFP/SFP+ ports for high-speed uplinks to other network devices or the core network.
- LCD displejs: Provides system status, configuration information, and error messages.
- Vadības pogas: Used to navigate and interact with the LCD display menu.
- Sistēmas statusa gaismas diodes: Indicators for power, alarm, and system status.
4.2 Aizmugurējais panelis

4.2. attēls: Leņķis View of EX4200-24P Switch. This image provides an angled perspective of the Juniper Networks EX4200-24P switch, highlighting the front panel with its 24 Ethernet ports and uplink module, and giving a partial view of the side chassis. The rear panel, not fully visible in this image, typically contains power input, fan modules, and a console port.
Aizmugurējais panelis parasti ietver:
- Maiņstrāvas savienotājs: Strāvas vada pievienošanai.
- Konsoles ports (RJ-45): For local management and initial configuration using a serial connection.
- USB ports: For software upgrades or configuration backup/restore.
- Ventilatora moduļi: Removable fan trays for cooling.
5. Iestatīšana un instalēšana
5.1 Vietnes sagatavošana
Before installation, ensure the installation site meets the following requirements:
- Vide: Maintain an ambient temperature between 0°C and 45°C (32°F and 113°F) and relative humidity between 10% and 85% (non-condensing).
- Jauda: A dedicated power outlet with proper grounding is recommended.
- Ventilācija: Ensure at least 5 cm (2 inches) of clearance at the front and rear for airflow.
5.2 Uzstādīšana uz plaukta
The EX4200-24P is designed for installation in a standard 19-inch equipment rack.
- Attach the provided rack-mount brackets to the sides of the switch using the supplied screws.
- Align the switch with the rack posts and secure it using appropriate rack screws.
5.3 Strāvas pieslēgums
- Connect one end of the power cord to the AC power connector on the rear panel of the switch.
- Pievienojiet strāvas vada otru galu iezemētai elektrotīkla kontaktligzdai.
- The switch will power on automatically. Observe the system status LEDs for initial boot-up.
5.4 Tīkla savienojumi
- Connect Ethernet cables from your network devices (computers, IP phones, wireless access points) to the RJ-45 ports on the front panel.
- For uplink connections to other switches or routers, insert appropriate SFP/SFP+ transceivers into the uplink module slot and connect fiber or copper cables as required.
- For initial configuration, connect a console cable from your management workstation to the console port on the rear panel.
6. Slēdža darbība
6.1 Power On and Initial Boot
Once connected to power, the switch will begin its boot sequence. The system status LEDs will indicate the boot progress. The LCD display will show system information during startup.
6.2. LED indikatori
Monitor the LEDs on the front panel to understand the switch's operational status:
- Sistēmas gaismas diode: Indicates overall system health (e.g., green for normal operation, amber for minor alarm, red for major alarm).
- Barošanas gaismas diode: Norāda jaudas stāvokli.
- Porta saites/aktivitātes gaismas diodes:
- Vienmērīgi zaļš: Saite izveidota.
- Mirgojošs zaļš: Activity on the port.
- Izslēgts: Nav saites.
- PoE statusa gaismas diodes: Indicate Power over Ethernet status for PoE-enabled ports.
6.3 Pamata konfigurācijas piekļuve
The switch can be configured via the command-line interface (CLI) through the console port or remotely via Telnet/SSH after initial IP configuration. Refer to the Juniper Networks documentation for detailed CLI commands and configuration guides.
- Konsoles ports: Izmantojiet termināļa emulatoru (piemēram, PuTTY) ar iestatījumiem: 9600 baudi, 8 datu biti, bez paritātes, 1 stopbits, bez plūsmas kontroles.
- Web Interfeiss: Some Juniper switches offer a web-based management interface. Check your specific firmware version for availability and default access details.
7. Apkope
7.1. Tīrīšana
Regular cleaning helps maintain optimal performance and extends the lifespan of the switch.
- Power off and disconnect the switch before cleaning.
- Ārējās virsmas noslaukšanai izmantojiet mīkstu, sausu drānu.
- Use compressed air to clear dust from ventilation openings and fan modules.
- Do not use liquid or aerosol cleaners directly on the switch.
7.2. Programmaparatūras atjauninājumi
Periodiski pārbaudiet Juniper Networks atbalstu website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security patches. Follow the instructions provided with the firmware package for proper installation.
7.3. Vides apsvērumi
Ensure the switch operates within its specified temperature and humidity ranges. Avoid blocking ventilation ports and ensure proper airflow to prevent overheating, which can lead to system instability or failure.
8. Traucējummeklēšana
Šajā sadaļā ir sniegti risinājumi bieži sastopamām problēmām, ar kurām jūs varētu saskarties.
8.1 Nav jaudas
- Pārliecinieties, vai strāvas vads ir droši pievienots gan slēdzim, gan elektrotīkla kontaktligzdai.
- Pārbaudiet, vai strāvas kontaktligzda darbojas, pievienojot tai citu ierīci.
- Ensure the power supply unit (if modular) is properly seated.
8.2 Nav savienojuma ostā
- Pārbaudiet Ethernet kabeļa savienojumu abos galos. Izmēģiniet citu kabeli.
- Pārliecinieties, vai pievienotā ierīce ir ieslēgta un darbojas pareizi.
- Pārbaudiet slēdža porta konfigurāciju (piemēram, ātrumu, dupleksa iestatījumus).
8.3 Tīkla savienojamības problēmas
- Confirm the switch has a valid IP address and network configuration.
- Pārbaudiet, vai tīklā nav IP adrešu konfliktu.
- Verify VLAN configurations if applicable.
- Restartējiet slēdzi un pievienotās ierīces.
8.4 Rūpnīcas atiestatīšana
A factory reset will erase all configurations and restore the switch to its default settings. Consult the Juniper Networks documentation for the specific procedure for the EX4200 series, as it typically involves a specific command sequence via the console port.
9. Tehniskās specifikācijas
| Funkcija | Specifikācija |
|---|---|
| Modelis | EX4200-24P |
| Zīmols | Kadiķu tīkli |
| Portu skaits | 24 x 10/100/1000BASE-T (PoE+) |
| Interfeisa veids | RJ45 |
| Produkta izmēri (LxWxH) | 23 x 22.75 x 11 collas (58.42 x 57.78 x 27.94 cm) |
| Preces svars | 23.1 mārciņas (10.48 kg) |
| Lietas materiāls | Plastmasa |
| Augšējā temperatūras reitings | 45 grādi pēc Celsija |
| UPC | 647213692099 |
| ASIN | B07PFLPRX6 |
10. Informācija par garantiju
This Juniper Networks EX4200-24P switch is offered as a renewed product. Warranty coverage for renewed products is typically provided by the seller, "Network Hardware Depot" in this case, or the Amazon Renewed program, not directly by Juniper Networks.
- Seller's Return Policy: The seller offers a return policy, typically 30 days for refund/replacement.
- Paplašinātās aizsardzības plāni: Additional protection plans may be available for purchase through Amazon or third-party providers.
- For specific warranty details and terms, please refer to the purchase agreement or contact the seller directly.
Legal Disclaimer from Seller: "We DO NOT accept RMA's or Returns for Non Defective Items. Any merchandise returned for repair and found NOT to be defective by our technicians will have a 25% restocking fee. There will be no exception to this policy. By placing a bid or order with us you have entered into a binding agreement that you acknowledge and accept our procedures. Additional warranty length is available, contact us directly for more details."
11. Atbalsts
For technical assistance, further documentation, or advanced configuration guides, please refer to the official Juniper Networks support website. For issues related to the renewed product's condition or seller-specific policies, contact the seller directly.
- Juniper Networks Support: www.juniper.net/us/en/support.html
- Pārdevēja kontaktpersona: Refer to your Amazon order details for seller contact information (Network Hardware Depot).