Jaycar Digitech QC1938 100MHz digitālā osciloskopa lietotāja rokasgrāmata

1. Ievads

This manual provides detailed instructions for the safe and effective operation of your Jaycar Digitech QC1938 100MHz Digital Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. Retain this manual for future reference.

2. Drošības informācija

Observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.

  • Barošanas avots: Connect the oscilloscope only to the power source specified in this manual.
  • Zemējums: Ensure the instrument is properly grounded to prevent electric shock.
  • Zondes: Use only probes supplied or recommended by the manufacturer. Ensure probes are rated for the voltage tiek mērīts.
  • Ventilācija: Neaizbloķējiet ventilācijas atveres. Nodrošiniet pietiekamu gaisa cirkulāciju ap instrumentu.
  • Vide: Operate the oscilloscope in a dry environment. Avoid exposure to moisture, dust, or extreme temperatures.
  • Apkope: Refer all servicing to qualified service personnel. Do not attempt to repair the instrument yourself.

3. Iepakojuma saturs

Pārliecinieties, vai jūsu iepakojumā ir visi tālāk norādītie priekšmeti:

  • Jaycar Digitech QC1938 Digital Oscilloscope
  • 10:1 Passive Probe with 1.5m lead
  • 2 x BNC to Clip Test Leads
  • USB kabelis
  • Strāvas svins
  • Lietotāja rokasgrāmata (šis dokuments)

4. Produkts beidziesview

The Jaycar Digitech QC1938 is a 100MHz Digital Oscilloscope designed for precise electronic measurements. It features a 7-inch color LCD screen, two independent channels, and a built-in waveform generator.

Priekšpuse view of the Digitech QC1938 Digital Oscilloscope displaying a sine wave on its screen.
4.1. attēls: Priekšpuse view of the Digitech QC1938 Digital Oscilloscope. This image shows the main display, control knobs, function buttons, and input connectors for channels 1 and 2, along with the USB port.
Leņķveida view of the Digitech QC1938 Digital Oscilloscope, highlighting the side ventilation and handle.
4.2. attēls: Leņķveida view of the Digitech QC1938 Digital Oscilloscope. This perspective emphasizes the robust build, integrated handle for portability, and side ventilation grilles.
Leņķveida view of the Digitech QC1938 Digital Oscilloscope displaying a complex waveform.
4.3. attēls: Vēl viens leņķisks view of the Digitech QC1938 Digital Oscilloscope. The screen displays a different waveform, demonstrating the device's capability to visualize various signal types.

Galvenās funkcijas:

  • 7-inch TFT color LCD screen with 800 x 480 pixel resolution
  • Two independent input channels
  • 100MHz bandwidth and 1GSa/s sampling likme
  • 8M memory depth (single channel)
  • Integrated 25MHz waveform generator (Sine, Square, Ramp, Exponential, Noise, DC)
  • Auto scale function for automatic sine and square wave detection
  • 14 trigger modes including Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, and IIC
  • 5 serial protocol triggers and decodes: RS232/UART, I2C, SPI, CAN, and LIN
  • Two 3-digit digital voltmeters and a 6-digit hardware frequency indicator
  • 32 types of auto measurements with real-time statistics
  • USB Host/Device interface for computer control and data storage

5. Iestatīšana

5.1 Strāvas pieslēgums

  1. Connect the supplied power lead to the power input on the rear panel of the oscilloscope.
  2. Plug the other end of the power lead into a grounded AC power outlet.
  3. Press the power button on the front panel to turn on the oscilloscope.

5.2 Zondes savienojums

  1. Connect the BNC connector of the passive probe to either Channel 1 (CH1) or Channel 2 (CH2) input on the front panel.
  2. Attach the ground clip of the probe to the circuit's ground point.
  3. Connect the probe tip to the test point in your circuit.
  4. Ensure the probe's attenuation setting (e.g., 1X or 10X) matches the setting on the oscilloscope for accurate readings.

6. Lietošanas instrukcijas

6.1 Pamatdarbība

  • Automātiska mērogošana: Press the 'AUTO SET' button to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display. This function detects sine and square waves automatically.
  • Vertical Controls (VOLTS/DIV, POSITION): Use the VOLTS/DIV knobs to adjust the vertical scale (voltage per division) for each channel. The POSITION knobs shift the waveform vertically.
  • Horizontal Controls (SEC/DIV, POSITION): Use the SEC/DIV knob to adjust the horizontal scale (time per division). The horizontal POSITION knob shifts the waveform horizontally.
  • Trigera līmenis: Adjust the 'TRIGGER LEVEL' knob to set the voltage level at which the oscilloscope captures a waveform.

6.2 Papildu funkcijas

  • Viļņu formas ģenerators: Access the waveform generator menu to select and configure output waveforms such as Sine, Square, Ramp, Exponential, Noise, and DC. Connect the 'WAVE GEN' output to your circuit.
  • Trigera režīmi: Utilize the 14 available trigger modes (Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC) to capture specific events. Select modes via the 'TRIGGER' menu.
  • Serial Protocol Decoding: The oscilloscope supports decoding for RS232/UART, I2C, SPI, CAN, and LIN protocols. Configure these settings in the 'DECODE' menu to view decoded data.
  • Mērījumi: The device offers 32 types of automatic measurements with real-time statistics (maximum, minimum, standard deviation, etc.). Access these via the 'MEASURE' menu.
  • USB savienojums: Connect a USB thumb drive to the USB Host port to save oscilloscope setups, waveforms, reference waveforms, CSV files, and images. The USB Device port allows for remote control from a computer using SCPI commands.

7. Apkope

7.1. Tīrīšana

Lai tīrītu instrumentu, izmantojiet mīkstu drānu dampened with a mild detergent solution. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.

7.2. Uzglabāšana

When not in use, store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. Use the original packaging or a suitable case for protection during transport.

8. Traucējummeklēšana

If you encounter issues with your oscilloscope, refer to the following common problems and solutions:

ProblēmaIespējamais cēlonisRisinājums
Nav jaudasPower cable not connected; Power outlet faulty; Power button not pressedCheck power cable connection; Test power outlet; Press power button firmly
Nav attēlota viļņu formaProbe not connected; Incorrect input channel selected; Vertical/Horizontal scale incorrect; Trigger level too high/lowConnect probe to CH1/CH2; Select correct channel; Adjust VOLTS/DIV and SEC/DIV; Adjust TRIGGER LEVEL or use 'AUTO SET'
Nestabila viļņu formaIncorrect trigger settings; No stable trigger sourceAdjust trigger level; Select appropriate trigger mode; Ensure a stable signal source
USB disks nav atpazītsUSB drive formatted incorrectly; Drive not fully insertedEnsure USB drive is FAT32 formatted; Re-insert USB drive firmly

Ja problēma joprojām pastāv pēc šo risinājumu izmēģināšanas, lūdzu, sazinieties ar klientu atbalsta dienestu.

9. Specifikācijas

ParametrsSpecifikācija
Displejs7 collu TFT krāsu LCD
Izšķirtspēja800x480 pikseļi
Displeja veidsPoint, Vector
Kanāli2
Joslas platums100 MHz
Sampling likmeUp to 1 GSa/s
Atmiņas dziļums8M (single channel)
Vertikālais diapazons2mV / div ~ 10V / div
Vertikālā izšķirtspēja8 bits
Viļņu formas ģeneratorsSinuss, kvadrāts, Ramp, Exponential, Noise, DC
InterfeissUSB resursdators, USB ierīce
Svars1.9 kg
Izmēri (G x A x W)318 mm x 150 mm x 110 mm

10. Garantija un atbalsts

Lai saņemtu informāciju par garantiju un tehnisko atbalstu, lūdzu, skatiet dokumentāciju, kas pievienota iegādes brīdī, vai sazinieties ar izplatītāju. Saglabājiet pirkuma apliecinājumu garantijas prasību iesniegšanai.

Saistītie dokumenti — QC1938

Iepriekšview Jaycar AA0378 programmējamā taimera programmēšanas rokasgrāmata
Šajā rokasgrāmatā ir detalizēti aprakstīta Jaycar AA0378 programmējamā taimera moduļa programmēšana, izskaidrotas releja funkcijas, tiltslēgu iestatījumi un sniegti praktiski piemēri.ampIeslēgšanas un izslēgšanas periodu iestatīšanas iespējas.
Iepriekšview Bezkontakta infrasarkanā termometra lietošanas instrukcija — modelis QM7221
QM7221 bezkontakta infrasarkanā termometra lietošanas rokasgrāmata, kurā detalizēti aprakstītas funkcijas, specifikācijas, darbība, drošība un apkope precīziem temperatūras mērījumiem.
Iepriekšview Ultraskaņas tīrītāja lietotāja instrukcija - YH5408
Visaptveroša YH5408 ultraskaņas tīrītāja lietotāja rokasgrāmata, kurā ietvertas svarīgas drošības vadlīnijas, detaļu apraksts, lietošanas instrukcijas, tīrīšanas metodes un apkopes padomi.
Iepriekšview Jaycar QC3150 viedā gredzena īsā lietošanas pamācība
Īsa pamācība par Jaycar QC3150 viedā gredzena iestatīšanu un lietošanu kopā ar uzlādes futrāli. Uzziniet par tā funkcijām un pamatdarbību.
Iepriekšview XC3800 ESP32 galvenā plate ar WiFi un Bluetooth — tehniskais pārskatsview un Iestatīšana
Detalizēta informācija par XC3800 ESP32 pamatplati, divkodolu mikrokontrolleri ar Wi-Fi un Bluetooth. Ietver iestatīšanas rokasgrāmatas Arduino IDE un MicroPython izstrādes vidēm.
Iepriekšview Jaycar XC5176 uzlādējama skaļruņa ar MP3 atskaņotāju lietotāja rokasgrāmata
Jaycar XC5176 uzlādējamā skaļruņa un MP3 atskaņotāja lietotāja rokasgrāmata. Uzziniet, kā droši un efektīvi lietot ierīci.