First Alert SMICO100-AC

First Alert SMICO100-AC Interconnect Hardwire Combination Smoke & Carbon Monoxide Alarm

Model: SMICO100-AC | Brand: First Alert

Ievads

The First Alert SMICO100-AC is an Interconnect Hardwire 2-in-1 Smoke & Carbon Monoxide Alarm with Battery Backup. It incorporates Precision Detection technology, designed to reduce nuisance alarms from cooking while providing early warning for fire and carbon monoxide hazards. This alarm is designed for easy installation and interconnection with compatible alarms, creating a comprehensive safety system throughout your home.

First Alert logo with text 'Most Trusted Brand in Fire Safety' and a family sitting on steps

Image: First Alert - Most Trusted Brand in Fire Safety.

Drošības informācija

BRĪDINĀJUMS! Carbon monoxide cannot be seen or smelled but can kill you. If the alarm sounds, follow these steps:

  1. Nospiediet pogu Test/Silence.
  2. Zvaniet neatliekamās palīdzības dienestam (ugunsdzēsības dienestam vai 911).
  3. Immediately move to fresh air - outdoors or by an open door/window.

SVARĪGI! This smoke alarm contains a maximum of 1.0 microcuries (37kBq) of Americium 241, a radioactive material. Distributed under U.S. NRC License No. 13-23889-01E and is made in compliance with U.S. NRC safety criteria in 10CFR32.27. The purchaser is exempt from any regulatory requirements.

Ieteicamais izvietojums

Install alarms on every level of your home and in every bedroom to ensure optimal protection. Proper placement is crucial for early detection of smoke and carbon monoxide.

Diagram showing recommended placement of smoke and carbon monoxide alarms in a house, including bedrooms, hallway, living room, kitchen, basement, and garage.

Image: Recommended placement diagram for smoke and CO alarms.

Man installing a smoke alarm on the ceiling, with a graphic indicating installation on every level and in every bedroom.

Image: Install alarms on every level and in every bedroom.

Uzstādīšana un uzstādīšana

The SMICO100-AC alarm is designed for hardwired installation and includes a 9V battery backup. It features a Quick Connect Plug for simplified wiring.

Pirms uzstādīšanas:

Uzstādīšanas soļi:

  1. Remove Old Alarm: Disconnect the old alarm from its wiring harness and mounting bracket.
  2. Wire New Harness: If your existing wiring harness is not compatible, use the new Quick Connect Plug provided. Connect the black wire to the hot wire, white to neutral, and orange to the interconnect wire (if applicable). Ensure all connections are secure with wire nuts.
  3. Montāžas kronšteins: Attach the new mounting bracket to the electrical box on the ceiling or wall. The bracket is designed to accommodate various screw arrangements.
  4. Pievienot trauksmi: Plug the wiring harness into the back of the SMICO100-AC alarm.
  5. Uzstādiet akumulatoru: The alarm comes with a pre-installed 9V Duracell battery. Remove the plastic tab to activate it.
  6. Secure Alarm: Novietojiet trauksmes ierīci ar montāžas kronšteinu un pagrieziet pulksteņrādītāja virzienā, līdz tā droši nofiksējas vietā.
  7. Atjaunot jaudu: IESLĒDZIET strāvu pie ķēdes pārtraucēja.
  8. Testa trauksme: Press and hold the Test/Silence button until the alarm sounds. Refer to the 'Operating Instructions' section for expected alarm patterns.
Atpakaļ view of the First Alert SMICO100-AC alarm showing the wiring harness connection point and battery compartment.

Attēls: Atpakaļ view of the alarm with wiring harness.

Close-up of the First Alert SMICO100-AC alarm showing the Quick Connect Plug for easy installation.

Image: Quick Connect Plug for easy installation.

Video: Detailed guide on hardwired smoke detector installation, including wiring and mounting.

Video: Demonstration of easy installation with a universal mount for the smoke and carbon monoxide alarm.

Lietošanas instrukcijas

The SMICO100-AC alarm provides distinct audible signals for smoke and carbon monoxide detection, as well as for low battery, malfunction, and end-of-life conditions.

Testa/klusuma poga:

Press and hold the Test/Silence button to test the alarm's functionality. The alarm will sound if working correctly. This button can also be used to temporarily silence nuisance alarms.

A hand pressing the test/silence button on the First Alert SMICO100-AC alarm installed on a ceiling.

Image: Hand pressing the Test/Silence button.

Alarm Guide:

Apkope

Regular maintenance ensures the continued reliability of your alarm. Gently vacuum or use clean compressed air to remove accumulated dust monthly. Never use water, cleaners, or solvents, as these may damage the unit. Press the test button after installation, weekly, and after cleaning to check all alarm functions.

Nomaiņas grafiks:

Replace the alarm at least every 10 years after installation to ensure optimal performance and safety.

Man testing a smoke alarm on the ceiling, with a graphic indicating to test alarms regularly.

Image: Test alarms regularly.

Woman holding a smoke alarm, with a graphic indicating to replace alarms at least every 10 years.

Image: Replace alarms at least every 10 years.

Video: Information on how often to replace First Alert detectors for optimal safety.

Video: Discussion on the importance of replacing old smoke detectors to maintain home safety.

Problēmu novēršana

If your alarm is chirping or sounding unexpectedly, refer to the Alarm Guide in the 'Operating Instructions' section to identify the specific issue. Common issues and their resolutions include:

Specifikācijas

FunkcijaDetaļas
Modeļa numursSMICO100-AC
Noteikšanas tipsSmoke (Ionization Sensor) & Carbon Monoxide
Barošanas avotsCieti savienots (120 V maiņstrāva) ar 9 V akumulatora rezerves barošanu
Akumulatora tips9 V sārmainā baterija (iekļauts komplektā)
SavienojumsYes, with compatible alarms
KrāsaBalts
Preces svars1.68 mārciņas
Produkta izmēri21.5 x 7.5 x 3.5 collas
RažotājsResideo
UPC029054022769

Garantija un atbalsts

For detailed warranty information and user manuals, please refer to the official First Alert webvietni vai sazinieties ar klientu atbalsta dienestu.

Saistītie dokumenti — SMICO100-AC

Iepriekšview First Alert SC7010BV dūmu un oglekļa monoksīda detektora lietotāja rokasgrāmata
Visaptveroša lietotāja rokasgrāmata First Alert SC7010BV ar maiņstrāvu darbināmam dūmu un oglekļa monoksīda detektoram, kurā detalizēti aprakstīta uzstādīšana, darbība, apkope, drošības funkcijas un problēmu novēršana.
Iepriekšview First Alert dūmu un oglekļa monoksīda detektoru lietotāja rokasgrāmatas
Visaptverošas lietotāja rokasgrāmatas First Alert 9120LBLA vadu dūmu detektoram un First Alert CO615A oglekļa monoksīda spraudkontakta detektoram, kurās aprakstīta uzstādīšana, darbība, apkope, drošība un problēmu novēršana.
Iepriekšview Pirmā brīdinājuma SMICO100-AC dūmu un oglekļa monoksīda trauksmes lietošanas rokasgrāmata
Comprehensive user manual for the First Alert SMICO100-AC Smoke and Carbon Monoxide Alarm, covering installation, operation, features, troubleshooting, and safety guidelines.
Iepriekšview First Alert Onelink Wi-Fi dūmu + oglekļa monoksīda detektora lietotāja rokasgrāmata AC10-500
Visaptveroša lietotāja rokasgrāmata First Alert Onelink AC10-500 Wi-Fi dūmu + oglekļa monoksīda detektoram, kurā aprakstīta uzstādīšana, darbība, apkope, problēmu novēršana un drošības informācija. Uzziniet par detektora funkcijām, novietojumu, iestatīšanu un ārkārtas procedūrām.
Iepriekšview First Alert BRK dūmu un dūmu/CO detektori: lietotāja rokasgrāmatas un uzstādīšanas rokasgrāmatas
Visaptverošas lietotāja rokasgrāmatas un uzstādīšanas ceļveži First Alert BRK 3120B-6 dūmu detektoram un SC7010BV dūmu un oglekļa monoksīda detektoram. Uzziniet par šo būtisko mājas drošības ierīču funkcijām, uzstādīšanu, drošību un problēmu novēršanu.
Iepriekšview First Alert SC7010B dūmu un oglekļa monoksīda detektora lietotāja rokasgrāmata
Visaptveroša lietotāja rokasgrāmata First Alert SC7010B maiņstrāvas dūmu un oglekļa monoksīda detektoram. Aptverta uzstādīšana, funkcijas, darbība, apkope, problēmu novēršana, normatīvā informācija un garantija.