1. Ievads un beigasview
The vLinker FS USB OBD2 Adapter is a professional-grade diagnostic tool designed for automotive enthusiasts and professionals. It specializes in working with FORScan software and provides advanced diagnostic and programming capabilities for various vehicle makes, particularly Ford, Lincoln, Mazda, and Mercury vehicles.
This manual provides detailed instructions for setting up, operating, maintaining, and troubleshooting your vLinker FS USB adapter to ensure optimal performance and safe usage.
2. Produkta īpašības
- FORScan Optimization: Specifically designed and recommended by the FORScan Team for reliable connection and high-speed data transfer.
- Fast and Stable Connection: Achieves 3Mpbs transmission rate and 3Mhz baud rate via USB 2.0/3.0, ensuring smooth data flow without dropped packets or corruption.
- Automatic Electronic Switching: Seamlessly switches between HS-CAN, MS-CAN, and Ford Car networks, allowing simultaneous access to all CAN buses.
- FEPS 18V Programming Voltage Izvade: Supports advanced programming functions within FORScan.
- Battery Saver and Protection: Features auto sleep/wake-up mode, over-voltage, over-current, over-temperature, and battery drain protection, allowing the device to remain plugged in safely.
- Plaša transportlīdzekļu saderība: Supports all 12V/24V OBD2 standard compliant cars (99% of models after 2000, 92% after 1996 in USA; 12V gasoline after 2000, 12V diesel after 2004 in EU).
- Pilnas OBD2 funkcijas: Capable of reading/clearing fault codes, accessing live data, I/M readiness, on-board monitor tests, O2 sensor tests, vehicle information, component tests, and freeze frame data.
- Support for Third-Party Apps: Compatible with FORScan, ELMconfig, ELM FF2, FoCCCus, and other OBD2 applications (apps not included).

Figure 2.1: The vLinker FS USB OBD2 Adapter with its integrated USB cable.

Figure 2.2: Diagram illustrating the automatic electronic switching capability between HS-CAN and MS-CAN, along with hacker-proof, battery saver, and overvoltage aizsardzības funkcijas.
3. Specifikācijas
| Atribūts | Vērtība |
|---|---|
| Zīmols | vLinker |
| Modelis | vLinker FS USB |
| Barošanas avots | Elektrība ar vadu |
| Produkta izmēri | 3.61 collu garums × 1.76 collu platums × 0.85 collu augstums |
| Operētājsistēmas saderība | Windows |
| Preces svars | 3.88 unces |
| Pārraides ātrums | Līdz 3 Mpbs |
| Pārbaudes ātrums | Līdz 3Mhz |
| Sērijas buferis | 8192 baiti |
| OBD Request Byte | Līdz 4128 XNUMX baitiem |
4. Iestatīšana un instalēšana
4.1. Iepakojuma saturs
Pirms turpināt, pārliecinieties, vai iepakojumā ir visi priekšmeti:
- 1 x vLinker FS USB Adapter
- 1 x Lietotāja rokasgrāmata (šis dokuments)
- 1 x iepakojuma kaste
4.2 Draiveru un programmatūras instalēšana
- Download FTDI USB Driver: Navigate to the official FTDI webvietne (www.ftdichip.com). Go to the "DRIVERS" section and select "VCP Drivers". Download the appropriate USB driver for your Windows operating system.
- Instalējiet USB draiveri: Follow the on-screen instructions to install the downloaded FTDI USB driver.
- Download Diagnostic Application: Download your preferred OBD2 diagnostic application (e.g., FORScan, ELMconfig, ELM FF2, FoCCCus) compatible with Windows. These applications are not included with the vLinker FS USB adapter and may require separate purchase or download.

Figure 4.1: Steps for downloading the FTDI driver and a compatible diagnostic application.
4.3 Connecting the Adapter to Your Vehicle and Computer
- Atrodiet OBD2 portu: Identify the OBD2 diagnostic port in your vehicle. This port is typically located under the dashboard on the driver's side.
- Pievienojiet adapteri transportlīdzeklim: Firmly plug the vLinker FS USB adapter into your vehicle's OBD2 port.
- Connect Adapter to Computer: Plug the USB end of the vLinker FS USB adapter into an available USB port on your Windows PC.
- Ieslēdziet aizdedzi: Turn your vehicle's ignition to the "ON" position (engine does not need to be running for most diagnostic functions).

Figure 4.2: Illustration of connecting the vLinker FS USB adapter to the vehicle's OBD2 port and a computer, followed by turning the ignition on.
5. Lietošanas instrukcijas
5.1 Basic Diagnostic Functions
Once the vLinker FS USB adapter is connected and recognized by your computer and diagnostic software, you can perform various functions:
- Lasīt kodus: Retrieve Diagnostic Trouble Codes (DTCs) from the vehicle's Engine Control Unit (ECU).
- Dzēst kodus: Clear DTCs from the ECU. Note that clearing codes does not fix the underlying issue.
- Datu straume: View real-time sensor data and parameters from the vehicle.
- I/M gatavība: Check the status of emission-related monitors to determine if the vehicle is ready for an emissions test.
- Borta monitora pārbaude: Access results of on-board diagnostic monitoring tests for specific components/systems.
- O2 sensora tests: Retrieve O2 sensor monitoring test results.
- Transportlīdzekļa informācija: Display vehicle information such as VIN (Vehicle Identification Number), CID (Calibration ID), and CVN (Calibration Verification Number).
- Komponentu pārbaude: Perform specific tests on vehicle components as supported by your diagnostic software.
- Iesaldēt rāmi: View a snapshot of vehicle operating conditions at the moment a fault code was set.

5.1. Attēls: beidziesview of the full OBD2 functions supported by the vLinker FS USB adapter.
5.2 Advanced Functions (FORScan Specific)
For users utilizing FORScan, the vLinker FS USB adapter unlocks advanced capabilities:
- Module Configuration and Programming: Modify vehicle settings and program new modules.
- Hidden Function Activation: Enable or disable various vehicle features (e.g., global window open/close, secure idle, turn signal flash count, disabled door ajar chime, reverse tilt mirrors, Bambi mod, tire size correction, heated steering wheel, disabled double horn honk, perpendicular park assist).
- Access to All CAN Buses: Simultaneously access HS-CAN, MS-CAN, and Ford Car networks without manual switching.

5.2. attēls: Piemample of FORScan hidden function activation using the vLinker FS USB adapter.
6. Apkope
6.1. Programmaparatūras atjauninājumi
To ensure optimal performance and access to the latest features, it is recommended to keep the vLinker FS USB firmware updated. Firmware updates are free for the lifetime of the product.
- Pievienojiet adapteri: Connect the vLinker FS USB adapter to your computer via USB.
- Identificējiet COM portu: Open your computer's Device Manager and identify the COM port assigned to the vLinker FS USB.
- Launch Update Tool: Use the official vLinker firmware update tool (downloadable from the official webvietne).
- Select COM Port and Baud Rate: In the update tool, select the identified COM port and set the default baud rate (e.g., 115200).
- Browse and Select Firmware File: Lejupielādējiet jaunāko programmaparatūru file from the official vLinker website. In the update tool, browse and select this firmware file.
- Sākt atjaunināšanu: Click the "Update" button to begin the firmware update process. During the update, the Blue (BT) light and Orange (Host) light on the adapter will remain on.
- Pabeigšana: Once the update is complete, the Red (OBD) light and Orange (Host) light will turn off. Power cycle the device (unplug and replug) for changes to take effect.
Svarīgi: If the update is interrupted or fails, unplug and replug the device, then re-attempt the update with the latest firmware from the official website. Pirated products cannot be updated.

Figure 6.1: Step-by-step guide for updating the vLinker FS USB firmware.
6.2 Tīrīšana un uzglabāšana
- Turiet adapteri tīru un bez putekļiem un gružiem. Tīrīšanai izmantojiet mīkstu, sausu drānu.
- Uzglabājiet adapteri vēsā, sausā vietā, pasargājot to no tiešiem saules stariem un ekstremālām temperatūrām.
- Avoid exposing the device to moisture or corrosive substances.
7. Traucējummeklēšana
7.1. Bieži sastopamās problēmas un risinājumi
- Issue: Product does not light up after firmware update.
- Iemesls: The update process was interrupted or failed.
- Līdzeklis: Unplug and replug the device. Download the latest firmware from the official website and re-attempt the update.
- Issue: "USB not recognized" error message on computer.
- Iemesls: Some laptop models with USB 3.0 controllers may not be fully compatible, or the driver is not correctly installed.
- Līdzeklis:
- Connect the vLinker FS USB to a different USB port on your computer.
- Connect the vLinker FS USB via a USB 2.0 hub.
- Manually install the FTDI USB driver: Go to the official FTDI webvietne (www.ftdichip.com), select "DRIVERS", click "VCP Drivers", and download the appropriate USB driver.
- Issue: Adapter not connecting to vehicle or software.
- Iemesls: Incorrect connection, ignition not on, or software configuration issues.
- Līdzeklis:
- Ensure the adapter is firmly plugged into the vehicle's OBD2 port and the computer's USB port.
- Pārliecinieties, vai transportlīdzekļa aizdedze ir ieslēgta (“ON”).
- Check your diagnostic software settings to ensure the correct COM port is selected for the vLinker FS USB.
- Confirm that the necessary drivers are installed correctly (refer to Section 4.2).
8. Garantija un atbalsts
The vLinker FS USB car diagnostic scanner comes with a 1 gadu garantija no pirkuma datuma.
vLinker provides lifetime Firmware FREE updates to ensure your device remains up-to-date with the latest features and improvements.
For any technical assistance, troubleshooting, or inquiries, vLinker offers round-the-clock tech support. Should you encounter any issues, including failure to connect the device or other operational problems, please contact the vLinker support team. They are available to provide fast responses and technical assistance.
You can typically find contact information for support on the official vLinker webvietnē vai caur mazumtirgotāju, kur prece tika iegādāta.