
CITADEL MESH
MIDI TOWER CASE

LIETOTĀJA ROKASGRĀMATA
PIEDERUMU IEPAKOJUMA SATURS

PANEĻA NOŅEMŠANA
PRIEKŠĒJĀ/SĀNU PANEĻA NOŅEMŠANA
- Take off the front panel by pulling carefully from the bottom of the panel
- Remove the left side panel by pulling on the pull tab & swinging the door outwards, then lift off the hinges at the back of the case.
- Remove the right side pane by removing the two rear thrum screws and sliding the panel backwards

MOTHERBOARD INSTALLA
SĒKLAPAS UZSTĀDĪŠANA
- Align your motherboard with the chassis to locate where the stand-offs should be installed Once done, remove the motherboard and fasten stand-offs accordingly
- Insert your motherboard I/O plate into the cutout at the rear of the case
- Place your motherboard into the chassis, making sure the rear ports fit into the I/O plate
- Use the provided motherboard screws to attach your motherboard to the chassis

BAROŠANAS APGĀDES UZSTĀDĪŠANA
BAROŠANAS APGĀDES UZSTĀDĪŠANA
- Place PSU in the bottom rear of the case, within the PSU shroud
- Izlīdziniet caurumus un nostipriniet ar skrūvēm

GRAFIKAS KARTES/PCI-E KARTES UZSTĀDĪŠANA
GRAFIKAS KARTES/PCI-E KARTES UZSTĀDĪŠANA
- Ja nepieciešams, noņemiet aizmugurējos PCI-E slota vākus (atkarībā no kartes slota izmēra)
- Carefully position and slide your PCI-E card into place, then secure with the add-on card screws supplied If mounting vertically, attach the vertical GPU mount to the PSU shroud, attach the Klink PCI-E Riser Cable (Sold separately). remove the rear PCI-E slot covers and put the card into place, mounting to the PCI-E Riser cable mount securely
- Remember to attach the other end of the PCI-E Riser cable to your motherboards PCI-E 16x slot

2.5″ SDD INSTALLATION (F)
2.5 collu SSD UZSTĀDĪŠANA (PRIEKŠĒJĀ)
- Align your drive over the screw holes and secure with screws from the rear

2.5 collu SDD UZSTĀDĪŠANA (R)
2.5 collu SSD UZSTĀDĪŠANA (AIZMUGURES)
Place your SSD on top of the HDD bracket and secure with screws

3.5 collu HDD UZSTĀDĪŠANA
3.5 collu HDD UZSTĀDĪŠANA
- Slide the drive into/onto the 3,5″ bay at the rear of the case
- Secure the drive on the both sides using the provided screws and hand tighten

TOP VENTILATORA UZSTĀDĪŠANA
TOP VENTILATORA UZSTĀDĪŠANA
- Remove the dust filter from the top of the case
- Align your fan(s) to the screw holes on the top of the chassis and secure with screws
- Replace your dust filter once secured

PRIEKŠĒJĀ/AIZMUGURĒJĀ VENTILATORA UZSTĀDĪŠANA
PRIEKŠĒJĀ/AIZMUGURĒJĀ VENTILATORA UZSTĀDĪŠANA
- Align your fan to the screw holes on the chassis and secure with screws

ŪDENS DZESĒŠANAS RADIATORI UZSTĀDĪŠANA
ŪDENS DZESĒŠANAS RADIATORI UZSTĀDĪŠANA
- Nostipriniet ventilatorus pie radiatora, pēc tam piestipriniet radiatoru šasijas iekšpusē, nostiprinot ar skrūvēm no ārpuses
I/O PANEĻA UZSTĀDĪŠANA
I/O PANEĻA UZSTĀDĪŠANA
Carefully check the labelling of each connector from the 1/0 panel to identify their function
Cross reference with the motherboard manual to locate where each wire should be installed, then secure one at a time, Please ensure they are installed in the correct polarity to avoid non-function or damage

Dokumenti / Resursi
![]() |
KOLINK ANL-INT Citadel Mesh Midi Tower korpuss [pdfLietotāja rokasgrāmata ANL-INT, ANL-INT Citadel Mesh Midi torņa korpuss, Citadel Mesh Midi torņa korpuss, Mesh Midi torņa korpuss, Midi torņa korpuss, Torņa korpuss |
